BMW X5 Owners & Service Manuals

BMW X5: Replacing Crankshaft Pulse Generator (N52, N52K, N51, N53)

IMPORTANT: Read and comply with notes on protection against electrostatic damage (ESD protection).

IMPORTANT: Aluminum-magnesium materials.

No steel screws/bolts may be used due to the threat of electrochemical corrosion.

A magnesium crankcase requires aluminum screws/bolts exclusively.

Aluminum screws/bolts must be replaced each time they arereleased.

The end faces of aluminum screws/bolts are painted blue for the purposes of reliable identification.

Jointing torque and angle of rotation must be observed without fail (risk of damage).

Necessary preliminary tasks:

NOTE: Installation location of pulse generator for crankshaft is underneath starter motor.

Preparatory tasks:

Detach plug (1) from crankshaft pulse generator (2).

Release screw.

Installation

Replace aluminum screws.

Tightening torque 12 14 2AZ.

Withdraw pulse generator (2) from crankcase.

Installation:

Replace sealing ring.

NOTE: Check stored fault messages. Now clear the fault memory.

Electronic Switching On Or Control Unit
Fig. 13: Locating Pulse Generator Plug

REPLACING INLET CAMSHAFT PULSE GENERATOR (N52, N52K, N51, N53)

IMPORTANT: Read and comply with notes on protection against electrostatic damage (ESD protection).

Necessary preliminary tasks:

Unlock plug (1) and remove.

Release bolt.

Installation:

Replace screw.

Tightening torque 12 14 3AZ.

Remove pulse generator (2).

Electronic Switching On Or Control Unit
Fig. 14: Locating Pulse Generator Plug

NOTE: Check stored fault messages.

Now clear the fault memory.

READ NEXT:

 Replacing Pulse Generator On Inlet Camshaft (N52K)

IMPORTANT: Read and comply with notes on protection against electrostatic damage (ESD protection). Necessary preliminary tasks: Read out fault memory of DME control unit; if necessary, work through

 Replacing Control Unit (DME)

IMPORTANT: Read and comply with notes on protection against electrostatic damage (ESD protection). Necessary preliminary tasks: Switch off ignition Disconnect battery negative lead. Remove microf

 Alternator With Drive

REPLACING ALTERNATOR BELT PULLEY Special tools required: 12 7 110. Remove and install alternator drive belt. Depending on alternator type, grip shaft with: hexagon socket multi-tooth socket or

SEE MORE:

 Intake Manifold

REMOVING AND INSTALLING INTAKE AIR MANIFOLD (N62) Remove acoustic cover. To remove, unfasten screws. Raise acoustic cover and remove towards front. Remove design cover, if equipped. Remove center of bulkhead. Remove intake hose. Remove injection pipe. On rear side of manifold, unlock and disco

 Microfilter

REPLACING MICROFILTER FOR INTERIOR VENTILATION Necessary preliminary tasks: Remove microfilter housing. Unclip catches (1) and remove microfilter (2). Installation: Reset Condition Based Service display according to factory specification. Fig. 69: Identifying Catches And Microfilter REPLACING R